Conducting hot P2V migrations with VMware Converter
Preparation is
the key to help prevent physical-to-virtual, or P2V, migration failures with
VMware Converter. In this tip, I'll give you step-by-step instructions on how
to prepare your server for a hot clone. (Most of these steps can be skipped
with cold clones, as the server's OS is not running during the conversion.)
In a previous
installment of this series, we talked about
What VMware
Converter will do, hot cloning (which is when you make a P2V migration while
the server is still online) vs. cold cloning (which is when you migrate after
the server is offline), and which servers you should probably stay away from
when using VMware Converter.
Below are the
steps you should take to prepare your server for conversion.
- Install
the Converter application on the server being migrated. If you are using
the Enterprise version you can do this remotely, but my preference is to
install Converter direcly on to the server a potential complication caused
by introducing another PC in the conversion process. If you have many
machines to convert this is not always practical. The Converter
application consists of two parts, the Agent component (Windows service)
and the Manager component (front end GUI). If you are running this on the
server directly you need both components. Otherwise if you are running it
remotely only the Agent component is needed.
- Once you
install the application on the server a reboot will be required if the
server OS is Windows NT 4.0 or 2000. This is because a special driver is
installed for the cloning process on those OS's, Windows XP and 2003
utilize the Volume Shadow Copy service instead. Also, it's best to use a
local administrator account when logging into the server to install the
application.
- The
following Windows services must be running for Converter to work properly:
Workstation, Server, TCP/IP Netbios Helper and Volume Shadow Copy (Windows
XP/2003, can be set to manual, just not disabled). Also, disable Windows
Simple File Sharing if your source server is running Windows XP.
- Make sure
the VMware Converter Windows service is running.
- Ensure you
have at least 200 MB free on your source server's C drive. Mirrored or
striped volumes across multiple disks should be broken; hardware RAID is
OK since it is transparent to the operating system. Converter sometimes
has issues converting dynamic disks, if you experience problems with them,
then cold clone instead.
- Disable
any antivirus software running on the source server.
- Shutdown
any applications that are not needed on the server.
- Run chkdsk
and defragment your source server's hard disks.
- Clean-up
any temporary and unnecessary files on the source server. The less data
that needs to be copied the better. This only applies when utilizing file
level cloning (more on that later).
- Keep users
off the server while cloning. Disable remote desktop and any shares if
possible.
- Ensure
required TCP/UDP ports are opened between the source server and
VirtualCenter (VC) and VMware ESX. Even if you select VirtualCenter as
your destination, the ports still need to be opened to the ESX server you
choose. The source server first contacts VC to create the VM and then ESX
to transfer the data to. Required ports are 443 and 902 (source to ESX/VC)
and 445 and 139 (converter to source and source to Workstation/Server).
These ports need to be opened on both OS firewalls and any network
firewalls sitting between your source and destination servers.
- Ensure
your network adapter speed/duplex matches your physical switch setting.
This can have a dramatic effect on your conversion speed. When cold
cloning it's best to set your physical switch port to Auto/Auto since this
is what the Windows PE ISO will default to.
- If
importing a VM or physical image the Windows version of the server running
Converter must be equal to or greater then the source. So, if your source
is Windows 2003, the server running Converter cannot be Windows 2000.
- For cold
cloning, the minimum memory requirements is 264 MB (will not work with
less then this amount), the recommended memory is 364 MB. Converter also
utilizes a RAM disk if you have at least 296 MB of memory available.
Making the
conversion
With these steps complete, we're ready to get started. Start the Converter Manager application and click the Import Machine button to start the Converter Wizard. Select your Source server, in this example we will choose Physical Computer. Select This Local Machine if running Converter on the source server, otherwise enter the hostname/IP and login information of the server to be converted. At the Source Data screen you have the option to select your disk volumes and re-size then larger or smaller if needed. Make sure you do not select any small utility partitions created by your hardware installation. What you decide here will determine which disk cloning method is used to copy your source data. If you do not change your drive sizes or increase them, then a block-level clone will be performed. If you decrease the size of your drives by any amount then a file-level clone will be performed instead.
With these steps complete, we're ready to get started. Start the Converter Manager application and click the Import Machine button to start the Converter Wizard. Select your Source server, in this example we will choose Physical Computer. Select This Local Machine if running Converter on the source server, otherwise enter the hostname/IP and login information of the server to be converted. At the Source Data screen you have the option to select your disk volumes and re-size then larger or smaller if needed. Make sure you do not select any small utility partitions created by your hardware installation. What you decide here will determine which disk cloning method is used to copy your source data. If you do not change your drive sizes or increase them, then a block-level clone will be performed. If you decrease the size of your drives by any amount then a file-level clone will be performed instead.
When a
block-level clone is performed, data is transferred from the source server disk
to the destination server disk block-by-block. This method is faster but
results in more data being copied (even empty disk blocks are copied). When a
file-level clone is performed, data is instead transferred file-by-file, which
is slower but results in less data being copied. So if you only have 5 GB of
data on a 40 GB drive, then only the 5 GB is copied. It's a trade-off between
the two methods between faster transfer speed versus reduced data size which
often results in about the same time to copy the data. One potential caveat
with the file-level copy is if you have a server with a huge amount of small
files, it can take days to copy the data, and will sometimes fail. I
experienced a server with 200,000+ 2 K files in one directory which brought the
conversion to a crawl. Once I removed these files it completed in a few hours.
Next choose
your destination server which is typically VirtualCenter (VC)/ESX. If you have
a VC server managing a destination ESX server, it is best to choose the VC
server first. Continue entering a VM name, host and datastore; at the Networks
screen you can select one or more NIC's and networks to connect to.
My preference
is to first connect the VM to an Internal Only vSwitch so it is isolated from
the source server and I can power it on while the source server is still up.
Once I verify that the newly created VM is functioning properly and I go
through the post-clone procedures, I shutdown the source server and move the VM
to the same network that the source server was on.
Finally select
whether or not to install VMware Tools, enter any OS customization if
necessary, select whether or not to power on the VM right after the conversion
completes and click the Finish button to start the conversion process. Once the
conversion starts you can monitor the progress in the task progress window.
In our final
part to this series we will discuss troubleshooting failed conversions and
post-conversion procedures.